The gas burner of AGB type is non-industrial equipment intended for domestic heating and provides ignition, combustion and protection functions. AGB gas burner is a superior finished product, with a monobloc constructive design, easy to operate and maintain and with a cost effective performance.
THE SAFETY AND AUTOMATION DEVICES |
• Close the supply circuit in case of gas supply fail • Adjust the set up temperature within 8ºC ÷ 33ºC • Provide draft protection (clogged stack) in case of supply fail • Control the pressure by means of the regulator comprised by the solenoid |
---|---|
TECHNICAL CHARACTERISTICS |
Fuel / Supply pressure: Natural gas (NG) 20 mbar - SR 3317 – Natural Gas.Quality Requirements Liquefied Natural Gas (LNG) 30 mbar - SR 66 – Liquefied petroleum gases. Requirements and test methods Apparatus performance class: 1 Weight [kg]: 1.2 ± 0.1 Supply connection: elbow fitting G3/8 Firebox material: metallic or ceramics Firebox negative pressure: 5÷10 mm H2O Combustion efficiency: minimum 98% |