SU-AD.R

GAS TREATMENT EQUIPMENT

Natural gas dehydration unit

SU-AD.R

MAIN CHARACTERISTICS of
Natural gas dehydration unit SU-AD.R

The gas flows through an adsorption column containing a desiccant bed that retains water. When the water content in the desiccant bed reaches the desiccant saturation value, the desiccant bed must be regenerated by means of a warm gas stream.

 

MODEL SU-AD.R
TECHNICAL CHARACTERISTICS Nominal flow rate: Q = 10.000 ÷ 12.000.000 Nm³/day
Nominal pressure: 6/16/25/40/50/64/80/100/150/250 bar
Role: to remove water vapour from natural gas stream at gas field/underground natural gas storage facility gathering system - natural gas national transportation system
Type: water vapour adsorption from the natural gas stream by means of desiccants (silica gel, active alumina, molecular sieves etc.)
Dehydrated gas water content: corresponding to the dew point of the water entrapped in the natural gas < -15°C at the maximum working pressure (according to SR 3317: 2003) or 7 lbs. water/mil. Sft³ (0,112 g water/Sm³) natural gas (according to API 12 GDU)
EQUIPMENT COMPONENTS Separators
Adsorbers
Heat exchangers
Gas filter
Gas filter
Instrumentation
Control panel which provides parameters display and data transfer

MORE INFORMATION
Natural gas dehydration unit SU-AD.R

Contact us
For further information, please fill out the form bellow: